SANT / Inline ultrasonic water meters
WM12
Ultrasonic water, screwed; 15-40 mm
Battery-operated meter, PN16, IP68, Class-B as labelled, RS485 Modbus with external 24 VDC in retail lists
MODEL OVERVIEW
What the WM12 offers
- Battery-operated meter, PN16, IP68, Class-B as labelled, RS485 Modbus with external 24 VDC in retail lists
Manufacturer’s documented description: SANT retail price list, August 2026, pp. 63–66. Options and qualifications above are retained as stated.
TECHNICAL DATA
WM12 specifications
| Parameter | Documented value |
|---|---|
| Measuring principle | ultrasonic inlineSANT retail price list, August 2026, 63–66 |
| Nominal diameter (DN) | 15, 20, 25, 32, 40S20 · 66 |
| Connections | BSP parallel screwed endsS20 · 66 |
| Sensor protection | IP68S20 · 66 |
| Power supply | Battery-operated meter; external 24 VDC for outputS20 · 66 |
| Included outputs | RS485 Modbus; requires external 24 VDCS20 · 66 |
| Pressure designation | PN16S20 · 66 |
| Standards claim | Class B as printedS20 · 66 |
Details to confirm for the offered configuration
These parameters are not established as exact-model values in this record. Some may not apply to this technology.
- Q1 m3 h
- Q2 m3 h
- Q3 m3 h
- Q4 m3 h
- Working pressure and temperature
- Approvals and scope
DUTY & SELECTION
Where to consider this type
Sensors compare sound travel in different directions through the water. The difference is used to calculate flow. Inline versions have a defined measuring body.
Installation and commissioning
Before the meter is selected
- Fluid acoustic conditions and bubbles
- Approved Q values and orientation
- Battery-life assumptions and power for outputs
- Forward/reverse total treatment and data availability
Before the system is handed over
- Confirm the installation drawing, orientation and access for service.
- Match the actual flow range and permitted pressure loss to the project.
- Record meter serial number, start reading and any output scaling.
- Commission communications against the receiving system and retain the test record.
Reading and communication
Documentation mentions: RS485. These may be optional or specific to a variant.
Discovery tags come from the documented description, including optional capabilities. Confirm inclusion and exact size/configuration.
A connected metering system is five parts: meter → interface or module → network or gateway → software → billing, dashboard or control system. A quotation should name who supplies and maintains each one. AMR-ready equipment may still require separately quoted radio, gateway, head-end and billing software.
Understand pulse, wired and wireless reading ↗Documents and purchase checks
Read the SANT technical reference → · Browse the source index
Source: SANT retail price list, August 2026, pp. 63–66. Reviewed 2026-09-09.
Ask for these before ordering
- Approved drawing for the exact model, size and configuration
- Serial-number calibration or factory test record
- Applicable approval certificate and exact scope
- Installation manual and required straight pipe
- Protocol/register map and output power requirements
- Option/accessory codes with included components
- Pressure-loss curve, flange drilling and face-to-face length
- Current written commercial and warranty terms
SPECIFY YOUR REQUIREMENT
Get a quotation for WM12
Tell us the size and quantity you need. Add the fluid, flow or output requirement if known. You can review and send the enquiry from your email app on the next page.
Compare related models
Similar technology does not mean equivalent performance. Compare exact configurations.