Established 1969 Hyderabad · supply across India040-27710537
Water meterMAHESH TRADING CORPORATIONWATER METERS & FLOW METERS
Menu
Electromagnetic flow meters family line illustration
Illustrative family drawing · actual LIV-EMF-CS-RTFE-002 configuration may differ

Lehry / Electromagnetic flow meters

LIV-EMF-CS-RTFE-002

Electromagnetic — Integral, 25-bar list

CS flange/housing, PTFE lining, SS316L electrodes

Supply from Hyderabad · India-wide delivery
Configuration, availability and commercial terms confirmed on quotation.

MODEL OVERVIEW

What the LIV-EMF-CS-RTFE-002 offers

Manufacturer’s documented description: Lehry DLP, 25 August 2025, pp. 47–48. Options and qualifications above are retained as stated.

Check these document differences

Flow span and configuration

Lehry remote EMF sheet, undated, p.4: DN100 8.4–140 m³/h

Lehry integral sheet p.3 and DLP 25 August 2025 p.47: DN100 8.4–339 m³/h. These scopes differ; request the offered configuration

Request written confirmation for the offered size and configuration before using either value.

Specification blocks

Lehry technical sheets contain differing size, temperature, IP and accuracy-basis blocks

Do not combine options across sheets. DLP pp.47–48 also distinguishes 16-bar and 25-bar configurations

Request written confirmation for the offered size and configuration before using either value.

TECHNICAL DATA

LIV-EMF-CS-RTFE-002 specifications

ParameterDocumented value
Measuring principleelectromagneticLehry DLP, 25 August 2025, 47–48
Accuracy statement±0.5 FSD as printed; confirm percent notation and calibrated full scaleS5 · 48
Accuracy basisFull-scale basis in list; differs from other sheet wordingS5 · 48
Fluid temperature0–70°C standard; 180°C on request in list. Other technical-sheet limits differ.S5 · 48
Working pressure and temperature25 bar maximum; temperature-dependent limits require confirmationS5 · 48
Wetted materialsPTFE liner; SS316L electrodeS5 · 48
ConnectionsANSI B16.5 Class 300S5 · 48
Sensor protectionIP67 integral / IP68 remote list wording; verify sensor and transmitter separatelyS5 · 48
Optional outputs4–20 mA / pulse / RS485; HART extra in list note, despite interface list wordingS5 · 48
Body materialCarbon steel ASTM A216 enclosure and flangeS5 · 48
Details to confirm for the offered configuration

These parameters are not established as exact-model values in this record. Some may not apply to this technology.

  • Q1 m3 h
  • Q2 m3 h
  • Q3 m3 h
  • Q4 m3 h
  • Approvals and scope

DUTY & SELECTION

Where to consider this type

The guidance below explains the technology. It does not extend this model’s documented service limits.

An electromagnetic meter, often called a mag meter or EMF meter, measures flow using the electrical signal induced when a conductive liquid moves through a magnetic field.

Full electromagnetic flow meters guide ↗

Installation and commissioning

Before the meter is selected

  • Lowest measured conductivity
  • Liner, electrode and seal compatibility
  • Full measuring tube, grounding and pipe profile
  • Integral/remote configuration, accuracy basis and simultaneous powered outputs

Before the system is handed over

  • Confirm the installation drawing, orientation and access for service.
  • Match the actual flow range and permitted pressure loss to the project.
  • Record meter serial number, start reading and any output scaling.
  • Commission communications against the receiving system and retain the test record.
Read the installation guide ↗

Reading and communication

Documentation mentions: Pulse output, 4–20 mA, RS485. These may be optional or specific to a variant.

Discovery tags come from the documented description, including optional capabilities. Confirm inclusion and exact size/configuration.

A connected metering system is five parts: meter → interface or module → network or gateway → software → billing, dashboard or control system. A quotation should name who supplies and maintains each one. AMR-ready equipment may still require separately quoted radio, gateway, head-end and billing software.

Understand pulse, wired and wireless reading ↗

Documents and purchase checks

Read the Lehry technical reference → · Browse the source index

Source: Lehry DLP, 25 August 2025, pp. 47–48. Reviewed 2026-09-09.

Ask for these before ordering

SPECIFY YOUR REQUIREMENT

Get a quotation for LIV-EMF-CS-RTFE-002

Tell us the size and quantity you need. Add the fluid, flow or output requirement if known. You can review and send the enquiry from your email app on the next page.

Price and lead time are quoted for the selected size and configuration.

No order or message is sent by this step.

Compare related models

Similar technology does not mean equivalent performance. Compare exact configurations.

← All Lehry models

Call 98490 02060Request quote →