Established 1969 Hyderabad · supply across India040-27710537
Water meterMAHESH TRADING CORPORATIONWATER METERS & FLOW METERS
Menu
Electromagnetic flow meters family line illustration
Illustrative family drawing · actual KPE-100 configuration may differ

Kranti / AEW / Electromagnetic flow meters

KPE-100

Electromagnetic family with differing document scopes

Obtain an exact model, size, liner, electrode, power and output configuration. The general catalogue, dated price list and project sheet must not be merged.

Supply from Hyderabad · India-wide delivery
Configuration, availability and commercial terms confirmed on quotation.

MODEL OVERVIEW

What the KPE-100 offers

Manufacturer’s documented description: AEW/136, 11 August 2026, pp. 11. Options and qualifications above are retained as stated.

Check these document differences

Diameter scope

General electromagnetic catalogue, undated, p.2: 15–3000 mm

AEW/136, 11 August 2026, p.11: price tables to 1200 mm; project KPE-100 sheet, undated, p.1: 25–300 mm

Request written confirmation for the offered size and configuration before using either value.

Configuration limits

General catalogue pp.2–3: 0.2–12 m/s; rubber 85°C / PTFE 150°C

Project KPE-100 sheet pp.1–2: 0.5–10 m/s; EPDM plus 120°C; confirm this combination

Request written confirmation for the offered size and configuration before using either value.

Table integrity

General catalogue p.2 has visibly shifted conductivity/repeatability labels

General catalogue p.3 flow table does not fully reconcile with stated velocity envelope; request calibrated span

Request written confirmation for the offered size and configuration before using either value.

TECHNICAL DATA

KPE-100 specifications

ParameterDocumented value
Measuring principleelectromagneticAEW/136, 11 August 2026, 11
Fluid temperaturePTFE: 150°C; hard rubber: 85°C in this scheduleS34 · 11
Wetted materialsSS316 standard electrode; PTFE or hard-rubber liner. Other electrodes on request.S34 · 11
ConnectionsASA150 through DN250; PN10 from DN300. PN16/PN25/ASA300 on request.S34 · 11
Transmitter protectionDie-cast enclosure IP67S34 · 11
Power supply230 VAC / 24 VDC / battery variants; choose oneS34 · 11
Battery life and assumptionsOptional battery version claims 3 years; operating assumptions not suppliedS34 · 11
Included outputs4–20 mA and RS485 stated standard in AEW/136S34 · 11
Optional outputsHART; telemetry; remote display with up to 5 m cableS34 · 11
Body materialSS304 measuring tube; aluminium die-cast enclosureS34 · 11
Electrode optionsHastelloy C / platinum / titanium / tantalum on requestS34 · 11
DisplayGraphic display; 16 × 2 line display wordingS34 · 11

Kranti electromagnetic brochure: published dimensions and flow

S38 p.3

Values preserved as printed. Flow endpoints do not consistently match the brochure velocity statement; do not use this table as a validated sizing schedule.

DN (mm) OD (mm) W (mm) H (mm) Face-to-face (mm) Minimum (m³/h) Maximum (m³/h)
15 88.9 66 90 200 0.03 6.4
20 98.4 66 98 200 0.11 11
25 107.9 66 108 200 0.18 18
32 117.5 69 118 200 0.29 29
40 127 79 127 200 0.45 45
50 152.4 79 152 200 0.71 71
65 177.8 79 178 200 1.19 119
80 190.5 79 191 200 1.81 181
100 228.6 108 229 250 2.83 283
125 254 106 254 250 4.42 442
150 279.4 155 280 300 6.36 636
200 342.9 171 343 350 11.3 1130
250 406.4 203 407 450 17.66 1766
300 450 240 483 500 25.43 2543
350 510 298 533 550 34.62 3462
400 570 336 597 600 45.22 4522
450 620 398 635 698 57.23 5723
500 675 450 700 768 70.65 7065
600 785 550 813 918 101.74 10174
Details to confirm for the offered configuration

These parameters are not established as exact-model values in this record. Some may not apply to this technology.

  • Q1 m3 h
  • Q2 m3 h
  • Q3 m3 h
  • Q4 m3 h
  • Working pressure and temperature
  • Approvals and scope

DUTY & SELECTION

Where to consider this type

The guidance below explains the technology. It does not extend this model’s documented service limits.

An electromagnetic meter, often called a mag meter or EMF meter, measures flow using the electrical signal induced when a conductive liquid moves through a magnetic field.

Full electromagnetic flow meters guide ↗

Installation and commissioning

Before the meter is selected

  • Lowest measured conductivity
  • Liner, electrode and seal compatibility
  • Full measuring tube, grounding and pipe profile
  • Integral/remote configuration, accuracy basis and simultaneous powered outputs

Before the system is handed over

  • Confirm the installation drawing, orientation and access for service.
  • Match the actual flow range and permitted pressure loss to the project.
  • Record meter serial number, start reading and any output scaling.
  • Commission communications against the receiving system and retain the test record.
Read the installation guide ↗

Reading and communication

No electronic output is established for the base record. Confirm a compatible pickup or communication variant if remote reading is required; do not assume another model’s output can be fitted.

Understand pulse, wired and wireless reading ↗

Documents and purchase checks

Read the Kranti / AEW technical reference → · Browse the source index

Source: AEW/136, 11 August 2026, pp. 11. Reviewed 2026-09-09.

Ask for these before ordering

SPECIFY YOUR REQUIREMENT

Get a quotation for KPE-100

Tell us the size and quantity you need. Add the fluid, flow or output requirement if known. You can review and send the enquiry from your email app on the next page.

Price and lead time are quoted for the selected size and configuration.

No order or message is sent by this step.

Compare related models

Similar technology does not mean equivalent performance. Compare exact configurations.

← All Kranti / AEW models

Call 98490 02060Request quote →