MODEL OVERVIEW
What the KAM-G offers
- IS 779:1994
- screwed ends
- use its own lower-flow limits rather than substituting Class-B values
Manufacturer’s documented description: AEW/136, 11 August 2026, pp. 2–7. Options and qualifications above are retained as stated.
Check these document differences
Working pressure / temperature
Kranti Besto leaflet, undated, p.1: 10 bar / 50°C
AEW/136, 11 August 2026, p.2: 16 bar / 45°C
Request written confirmation for the offered size and configuration before using either value.
TECHNICAL DATA
KAM-G specifications
| Parameter | Documented value |
|---|---|
| Measuring principle | multijetAEW/136, 11 August 2026, 2–7 |
| Nominal diameter (DN) | 15, 20, 25, 40, 50S34 · 2 |
| Accuracy statement | ±2% at Qt/Qn/Qmax; ±5% at QminS34 · 2 |
| Accuracy basis | Legacy flow-zone error bands; not one accuracy percentage across all flow ratesS34 · 2 |
| Fluid temperature | Maximum 45 °CS34 · 2 |
| Working pressure and temperature | Maximum 16 bar; confirm pressure/temperature deratingS34 · 2 |
| Connections | Screwed ends; verify exact thread and union drawingS34 · 2 |
| Body material | Brass IS 1264 DCB2S34 · 2 |
| Standards claim | IS 779:1994; ISI-marked Class A claimS34 · 2 |
Details to confirm for the offered configuration
These parameters are not established as exact-model values in this record. Some may not apply to this technology.
- Q1 m3 h
- Q2 m3 h
- Q3 m3 h
- Q4 m3 h
- Approvals and scope
DUTY & SELECTION
Where to consider this type
Several jets drive the impeller around its circumference. Multijet products are widely represented in domestic and small commercial catalogue ranges.
Installation and commissioning
Before the meter is selected
- Standard and edition behind Class A/Class B wording
- The exact model’s low-flow limits
- Wet/dry register and magnetic coupling
- Hot-water version, pulse pickup and counter scope
Before the system is handed over
- Confirm the installation drawing, orientation and access for service.
- Match the actual flow range and permitted pressure loss to the project.
- Record meter serial number, start reading and any output scaling.
- Commission communications against the receiving system and retain the test record.
Reading and communication
No electronic output is established for the base record. Confirm a compatible pickup or communication variant if remote reading is required; do not assume another model’s output can be fitted.
Understand pulse, wired and wireless reading ↗Documents and purchase checks
Read the Kranti / AEW technical reference → · Browse the source index
Source: AEW/136, 11 August 2026, pp. 2–7. Reviewed 2026-09-09.
Ask for these before ordering
- Approved drawing for the exact model, size and configuration
- Serial-number calibration or factory test record
- Applicable approval certificate and exact scope
- Installation manual and required straight pipe
- Protocol/register map and output power requirements
- Option/accessory codes with included components
- Pressure-loss curve, flange drilling and face-to-face length
- Current written commercial and warranty terms
SPECIFY YOUR REQUIREMENT
Get a quotation for KAM-G
Tell us the size and quantity you need. Add the fluid, flow or output requirement if known. You can review and send the enquiry from your email app on the next page.
Compare related models
Similar technology does not mean equivalent performance. Compare exact configurations.