Issue Evidence and consequence
Older Kranti mechanical limits differ Besto leaflet 10 bar/50°C versus AEW/136 16 bar/45°C; specify exact model and approved drawing [S14 p.1; S34 p.2]
Misleading hot filename S19 is named HOT but its performance page prints 45°C and lists hot as an option; it is not sufficient proof of supplied hot-water construction
Kranti turbine temperature / size Brochure 120°C and 200 NB versus dated KPT-100 entry 90°C and 150 mm; confirm model build [S32; S34 p.13]
Kranti EMF table alignment and span Conductivity/repeatability/display labels visibly shifted; flow table inconsistent with velocity wording [S38 pp.2-3]
Project KPE rubber temperature EPDM liner plus 120°C in project sheet versus general rubber limit 85°C [S15; S38]
Lehry EMF performance blocks conflict Size, IP, temperature, accuracy basis and DN100 max 140 versus 339 m³/h differ [S9; S21; S5]
SANT WM2 table errors DN250 Qt<Qmin, ambiguous units, different nominal flows and 45/50°C limits [S37; S33]
SANT WM13 output/flanges Battery label with external 24 V output power; Class150 versus PN16 drilling [S27 p.5; S33 p.66]
Fedrel vertical model identity Older FM106 brass/FM107 DI versus newer FM106 DI [S28; S17 p.4]
Fedrel EMF configurations 2022 pressure/output options and size ranges differ from 2026 list; avoid combining all best values [S22; S17 pp.8-10]
Sewage/irrigation loading “30% load” lacks solids/particle-size definition; do not generalize to raw sewage with rags/fibres [S5 p.46; S17 p.6]
Incomplete approvals Logos, ISI/MID/CGWA/board claims are in brochures; model/size/certificate validity not independently checked