Established 1969 Hyderabad · supply across India040-27710537
Water meterMAHESH TRADING CORPORATIONWATER METERS & FLOW METERS
Menu
Inline ultrasonic water meters family line illustration
Illustrative family drawing · actual LIV-UDWM-PPR-WOB-R250-001 configuration may differ

Lehry / Inline ultrasonic water meters

LIV-UDWM-PPR-WOB-R250-001

Ultrasonic water meter

PPR, screwed, 24 V, no battery, R250, T30, IP68, Class2, MAP16, RS485

Supply from Hyderabad · India-wide delivery
Configuration, availability and commercial terms confirmed on quotation.

MODEL OVERVIEW

What the LIV-UDWM-PPR-WOB-R250-001 offers

Manufacturer’s documented description: Lehry DLP, 25 August 2025, pp. 49–50. Options and qualifications above are retained as stated.

TECHNICAL DATA

LIV-UDWM-PPR-WOB-R250-001 specifications

ParameterDocumented value
Measuring principleultrasonic inlineLehry DLP, 25 August 2025, 49–50
Nominal diameter (DN)15, 20S5 · 49
R ratio250S5 · 49
Fluid temperatureT30S5 · 49
Working pressure and temperatureMAP16 as printedS5 · 49
ConnectionsScrewed endsS5 · 49
Sensor protectionIP68S5 · 49
Power supply24 V, without batteryS5 · 49
Included outputsRS485S5 · 49
Documented size scope15/20 mmLehry DLP, 25 August 2025, 49–50
Body materialPPRS5 · 49
Standards claimAccuracy Class 2 as printedS5 · 49
Details to confirm for the offered configuration

These parameters are not established as exact-model values in this record. Some may not apply to this technology.

  • Q1 m3 h
  • Q2 m3 h
  • Q3 m3 h
  • Q4 m3 h
  • Approvals and scope

DUTY & SELECTION

Where to consider this type

The guidance below explains the technology. It does not extend this model’s documented service limits.

Sensors compare sound travel in different directions through the water. The difference is used to calculate flow. Inline versions have a defined measuring body.

Full inline ultrasonic water meters guide ↗

Installation and commissioning

Before the meter is selected

  • Fluid acoustic conditions and bubbles
  • Approved Q values and orientation
  • Battery-life assumptions and power for outputs
  • Forward/reverse total treatment and data availability

Before the system is handed over

  • Confirm the installation drawing, orientation and access for service.
  • Match the actual flow range and permitted pressure loss to the project.
  • Record meter serial number, start reading and any output scaling.
  • Commission communications against the receiving system and retain the test record.
Read the installation guide ↗

Reading and communication

Documentation mentions: RS485. These may be optional or specific to a variant.

Discovery tags come from the documented description, including optional capabilities. Confirm inclusion and exact size/configuration.

A connected metering system is five parts: meter → interface or module → network or gateway → software → billing, dashboard or control system. A quotation should name who supplies and maintains each one. AMR-ready equipment may still require separately quoted radio, gateway, head-end and billing software.

Understand pulse, wired and wireless reading ↗

Documents and purchase checks

Read the Lehry technical reference → · Browse the source index

Source: Lehry DLP, 25 August 2025, pp. 49–50. Reviewed 2026-09-09.

Ask for these before ordering

SPECIFY YOUR REQUIREMENT

Get a quotation for LIV-UDWM-PPR-WOB-R250-001

Tell us the size and quantity you need. Add the fluid, flow or output requirement if known. You can review and send the enquiry from your email app on the next page.

Price and lead time are quoted for the selected size and configuration.

No order or message is sent by this step.

Compare related models

Similar technology does not mean equivalent performance. Compare exact configurations.

← All Lehry models

Call 98490 02060Request quote →